Hidden fields
Books Books
" Abbe-Zeiss refractometer was employed, a small amount of a concentrated solution of pure gutta in chloroform placed on each of the prisms and allowed to stand until the odor of chloroform had entirely disappeared. The prisms were then closed, and kept... "
Annual Report of the Directory of Lands - Page 559
by Philippines. Bureau of Lands - 1903
Full view - About this book

Report of the Philippine Commission to the Secretary of War ... 1900 ..., Part 1

United States. Philippine Commission (1900-1916) - 1903 - 1000 pages
...chloroform had entirely disappeared. The prisms were then closed and kept at a temperature of 70° C. until the readings became constant, showing that all...samples. The rotation was determined in chloroform, 0.5 percent solutions being used because, when more concentrated, the absorption of light was too great...
Full view - About this book

Publications - Bureau of Government Laboratories, Issue 7

Biology - 1903 - 133 pages
...chloroform had entirely disappeared. The prisms were then closed, and kept at a temperature of 70° C. until the readings became constant, showing that all...rotation was determined in chloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption of light was too great to admit...
Full view - About this book

The Gutta Percha and Rubber of the Philippine Islands

Penoyer L. Sherman (jr.) - Gutta-percha - 1903 - 146 pages
...chloroform had entirely disappeared. The prisms were then closed, and kept at a temperature of 70° C. until the readings became constant, showing that all...rotation was determined in chloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption of light was too great to admit...
Full view - About this book

Publications, Issues 1-10

Philippines. Bureau of Government Laboratories - 1902 - 900 pages
...chloroform had entirely disappeared. The prisms were then closed, and kept at a temperature of 70° C. until the readings became constant, showing that all...rotation was determined in chloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption of light was too great to admit...
Full view - About this book

The Gutta Percha and Rubber of the Philippine Islands

Penoyer L. Sherman (jr.) - Gutta-percha - 1903 - 142 pages
...and kept at a temperature of 70 C. until the readings became constant, showing that all chloro form had evaporated. The above figures are the results...rotation was determined in chloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption of light was too great to admit...
Full view - About this book

Report of the Governor General of the Philippine Islands, Part 2

Philippines. Governor - Philippines - 1904 - 1363 pages
...chloroform had entirely disappeared. The prisms were then closed, and kept at a temperature of 70° C. until the readings became constant, showing that all...determinations made with carefully prepared samples. The physical tests given in the above table are so diversified as to bring out clearly the extent of resemblance...
Full view - About this book

Publications, Issues 1-7

Philippines. Bureau of Government Laboratories - 1904 - 576 pages
...made with carefully prepared samples. The rotation was determined in chloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption...accurate readings. The physical tests given in the above tables are so diversified as to bring out clearly the extent of resemblance between the various samples...
Full view - About this book

Report of the Governor General of the Philippine Islands, Part 3

Philippines. Governor - Philippines - 1907 - 844 pages
...chloroform had entirely disappeared. The prisms were then closed and kept at a temperature of 70° C. until the readings became constant, showing that all...carefully prepared samples. The rotation was determined in choloroform, 0.5 per cent solution being used, because, when more concentrated, the absorption of light...
Full view - About this book

Annual Reports of the Secretary of War, Volume 9

United States. War Department - 1907 - 844 pages
...chloroform had entirely disappeared. The prisms were then closed and kept at a temperature of 70° ('. until the? readings became constant, showing that...made with carefully prepared samples. The rotation wao determined in choloroform, 0.5 per cent solution being used, because, when more concentrated, the...
Full view - About this book

Report of the Philippine Commission, Part 3

United States. War Department - Agriculture - 1907 - 846 pages
...being used. ргерапч! samples. The rotation was etermine n eooroforni, 0.5 per cent soluton beng used. because, when more concentrated, the absorption...accurate readings. The physical tests given in the abo\ с tables are so diversified as to bring out clearly the extent of resemblance between the various...
Full view - About this book




  1. My library
  2. Help
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF