Recommended Minimum Requirements for Plumbing: Report of Subcommittee on Plumbing of the Building Code Committee |
Contents
1 | |
2 | |
3 | |
4 | |
5 | |
7 | |
8 | |
10 | |
108 | |
111 | |
112 | |
113 | |
115 | |
116 | |
117 | |
118 | |
11 | |
12 | |
13 | |
17 | |
18 | |
19 | |
20 | |
21 | |
22 | |
23 | |
24 | |
25 | |
26 | |
27 | |
28 | |
29 | |
30 | |
31 | |
32 | |
33 | |
34 | |
35 | |
36 | |
37 | |
38 | |
39 | |
40 | |
41 | |
42 | |
43 | |
44 | |
45 | |
46 | |
47 | |
48 | |
49 | |
50 | |
51 | |
52 | |
53 | |
54 | |
60 | |
62 | |
63 | |
64 | |
65 | |
67 | |
74 | |
75 | |
77 | |
78 | |
102 | |
107 | |
123 | |
125 | |
127 | |
128 | |
131 | |
132 | |
135 | |
138 | |
139 | |
140 | |
142 | |
143 | |
144 | |
145 | |
146 | |
149 | |
150 | |
153 | |
154 | |
155 | |
156 | |
157 | |
158 | |
165 | |
166 | |
169 | |
172 | |
174 | |
177 | |
178 | |
179 | |
180 | |
181 | |
182 | |
183 | |
184 | |
185 | |
186 | |
187 | |
188 | |
192 | |
200 | |
202 | |
203 | |
206 | |
212 | |
219 | |
225 | |
241 | |
242 | |
250 | |
253 | |
Other editions - View all
Common terms and phrases
3-inch soil stack 3-inch stack acid approximately aspirating effects back pressure base bathtub bend brass building carbon carbon dioxide carbonic acid cast-iron closed combined committee connection corrosion discharge curve drainage system experiments factor of safety fittings fixture traps fixture units Fixtures discharged flush valve foot gallons per minute horizontal branch horizontal waste house drain house sewer hydrogen ion inch of water increase inlet installed iron laundry trays less limits mean rate metal number of fixture outlet oxygen peak discharge peak load plain traps plumber plumbing fixtures plumbing system pounds minimum protect rate of discharge rate of supply roof rush period rust sanitary self-siphonage siphonage soil or waste stack tops tank tions Total discharge trap seal vent pipe vent requirements vent stack vertical stack vitrified clay pipe washbasin waste pipe waste stack water supply water-closets weight wrought iron
Popular passages
Page 274 - Inspector, free of cost, all reasonable facilities to satisfy him that the rivets are being furnished in accordance with these specifications. All tests and inspection shall be made at the place of manufacture, prior to shipment, unless otherwise specified, and shall be so conducted as not to interfere unnecessarily with the operation of the works.
Page 280 - ... works which concern the manufacture of the material ordered. The manufacturer shall afford the inspector, free of cost, all reasonable facilities to satisfy him that the material is being furnished in accordance with these specifications. All tests (except check analyses) and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not to interfere unnecessarily with the operation of the works.
Page 277 - Samples so prepared shall be divided into three equal parts, each of which shall be placed in a sealed package, one for the manufacturer, one for the purchaser, and one for an umpire, if necessary.
Page 256 - A plaster-of-Paris filet 1 in. wide shall be cast along the length of the crown of the pipe to equalize the lower bearing before the upper one is brought into contact. Both of the bearings shall be sufficiently rigid to transmit and receive uniform loads throughout their lengths without deflection, and shall be so attached to the machine as to transmit and receive the maximum stresses produced by the tests without lost motion, vibration or sudden shock.
Page 265 - ... tons or fraction thereof above this amount. In case of a change of mixture during the heat, one set of two bars shall also be cast for every mixture other than the regular one. Each set of two bars is to go into a single mold. The bars shall not be rumbled or otherwise treated, being simply brushed off before testing.
Page 256 - The test load shall be applied through the upper bearing block in such a way as to leave the bearing free to move in a vertical plane passing midway between the lower bearings. In testing a pipe which is "out of straight...
Page 6 - LO Howard, chief of the Bureau of Entomology of the United States Department of Agriculture, and...
Page 36 - Old house sewers and drains may be used in connection with new buildings or new plumbing only when they are found, on examination and test, to conform in all respects to the requirements governing new sewers or drains, as prescribed in this code.
Page 46 - The air test shall be used in testing the sanitary condition of the drainage or plumbing system of all buildings where there is reason to believe that it has become defective. In buildings...
Page 18 - A trap is a fitting or device so constructed as to prevent the passage of air or gas through a pipe without materially affecting the flow of sewage or waste water through it. Trap seal.