EXHIBIT B-REGISTER OF AUTHORITY FOR EXPENDITURE

Specifications—Form as here shown. Size 14x17 inches. Printed on white medium ledger paper; all lines and printing black. Horizontal lines five to the inch.

Instructions for use-As each project is authorized, the number, date, location, description and estimated cost should be entered on this form in order of the numbers assigned. As the completion reports are submitted the remaining information called for on the form should be entered at once.

This form is designed to be kept in a loose-leaf binder. One book should be kept for each owning company. EXHIBIT C_EQUIPMENT COMPLETION REPORT

Specifications Forms as here shown. Size 11x17 inches. All lines and printing black.

Instructions for use—A report must be prepared on this form for each equipment project by the designated officer, as soon after completion as possible, listing and describing the units of equipment affected and giving careful description of the changes made and listing the units involved, both added and retired, with the costs of each. If a project involves changes in a number of units completed in more than one six months' period a progress report should be made covering the changes completed in each six months' period. When the whole project is finished a_final report shall be prepared covering all the changes made under the A. F. E., which will be a summary of all the semi-annual progress reports.

[blocks in formation]

Authority

Total

Date

COSTS INCURRED

Equipment, unit or seres affected by

the change

Lesse

De ption of Equipment to
which the change la applicable.

Description of the change
effected and of the other items
contributing to the cools incurred.

COSTS RETIRED
Cr
Acct

Amount
Na

A FE Na

of units affected

Change

Acct.
Ne.

Amount

[ocr errors]

of the above marmed company do wear that the foregoing report of property changes which were made under my supervision is true to the best of my knondesign and belief

Nare)
Subscribed and worn to before me this

day of

(Signatura)

[merged small][ocr errors]

Appendix D

(6) CONVENTIONAL SIGNS FOR ARCHITECTURAL

DETAILS

A. M. BLANCHARD, Chairman; ARMSTRONG CHINN, HENRY LEHn, W. F. OGLE, Sub-Committee.

The Electrical Wiring Symbols as shown, Exhibit D, have been adopted by the National Electrical Contractors' Association and the American Institute of Architects and therefore it is the opinion of your SubCommittee that these symbols should be proposed for approval and adoption.

Below (see Exhibit E) is given a list of Architectural Symbols which have been prepared for conventional representations of architectural details. The information incorporated in the list has been gathered from all sources available and the best of the symbols have been shown.

Exhibit D

This specification is based upon the use of the following standard symbols adopted by the National Electrical Contractors' Association and the American Institute of Architects.

(Copyrighted.)

[ocr errors]

Ceiling Outlet; Electric coly. Numeral in center indicate number of Standard 16 C. P. Ioanndoscect Lampa.

Ceiling Outlet: Combination. I indicates 4-16 C. P. Standard Incandescent lamps and a Gas Buroors. If gas only

Bracket Outlet; Electric only. Numeral inscenter indicatos number of Standard 16 C. P. Incandescent Lamps.

Bracket Outlet; Combination. findicates 4-16 C. P. Standard lacandescent lamps and a Gas Burners. Il gas only

[ocr errors]

Wall or Baseboard Receptacle Outlet. Numeral in center indicates number of Standard 16 C. P. Incandescent Lamps
Ploor Qutlet. Numeral in center indicatos number of Standard 16 C. P. Incandescent Lamps.

Outlet for Outdoor Standard or Pedestal; Electric only. Numeral indicates number of Standard 16 C. P. Incand't Lamps.

[ocr errors]

Outlet for Outdoor Standard or Pedestal; Combination. 4 indicates 6-16 C. P. Standard lacand'ı Lamps; 6 Gas Burders.

Drop Cord Outlet.

One Light Outlot, for Lamp Roceptacle.

Arc Lamp Outlet.

Special Outlet, for Lighting, Heating and Power Current, as described in Specifications

Ceiling Fan Outlet

S'
S2
$3 3-Way Switch Outlet
S4
SO
Se Electrolier Switch Outlet

S P. Switch Outlet

D. P. Switch Outlet.

Show as many Symbols as there are Switches. Or in case of a very largo group

of Switches, indicate number of Switches by a Roman numeral, thus Si XII; meaning 1. Single Pole Switches.

4-Way Switch Outlet

Describe Type of Switch in Specifications, that is,

Flush or Surface, Push Button or Snap

Automatic Door Switch Outlet

1

Meer Outlet

Distribution Panel.

Junction or Pull Box

Motor Outlet; Numeral in center indicates Horse Power.

Motor Control Outlet.

Tragsformer

Main or Feeder run concealed under floor.

Main or Feeder run concealed under Floor above.

Main or Feeder run exposed,

Branch Circuit run concealed under Floor.

Heights of Center of Wall Outlets (unless otherwise
specified):

Living Rooms sit. 6 ins
Chambers

stt. o ins,
Offices

6 ft. o ias Corridors

6 ft. 3 ins. Height of Switches (unless otherwise specified)

.ft.. in

Branch Circuit run concealed under Floor above.

Branch Circuit run exposed.

Pole Line

Exhibit D

This specification is based upon the use of the following standard symbols adopted by the National Electrical Contractors' Association and the American Institute of Architects.

(Copyrighted.)

[merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][ocr errors][merged small]

Circuit for Clock, Telophone, Bell or other Service, run undor Floor, concealed.
Kind of Service wanted ascertained by Symbol to which lino consects.

{

Circuit for Clock, Telephone, Bell or other Service, run ander Floor above, concealed
Kind of Service waoted ascertained by Symbol to which line connects.