EXHIBIT B-REGISTER OF AUTHORITY FOR EXPENDITURE

Specifications, Form as here shown. Size 14x17 inches. Printed on white medium ledger paper; all lines and printing black. Horizontal lines five to the inch.

Instructions for use- - As each project is authorized, the number, date, location, description and estimated cost should be entered on this form in order of the numbers assigned. As the completion reports are submitted the remaining information called for on the form should be entered at once.

This form is designed to be kept in a loose-leaf binder. One book should be kept for each owning company. EXHIBIT C-EQUIPMENT COMPLETION REPORT

Specifications-Forms as here shown. Size 11x17 inches. All lines and printing black.

Instructions for use-A report must be prepared on this form for each equipment project by the designated officer, as soon after completion as possible, listing and describing the units of equipment affected and giving careful description of the changes made and listing the units involved, both added and retired, with the costs of each. If a project involves changes in a number of units completed in more than one six months' period a progress report should be made covering the changes completed in each six months' period. When the whole project is finished a_final report shall be prepared covering all the changes made under the A. F. E., which will be a summary of all the semi-annual progress reports.

[blocks in formation]

Authority

COSTS INCURRED

Equipment, unit
numbers, names
or seres affected by

the change

Owner

Lessee

Total
number
of units
affected

Description of Equipment to
which the change is applicable.

Description of the change
effected and of the other items
contributing to the costs incurred.

Date

of
Change

COSTS RETIRED
CR
Acct

Amount
No.

AFENA

Aact
Na

Amount

[ocr errors][merged small]

of the above named company do wear that the foregoing report of property changes which were made under my supervision is true to the best of my knowdedge and belief

Name)
Subscribed and sworn to before me this

day of

(Signature)

[merged small][ocr errors]

Appendix D

(6) CONVENTIONAL SIGNS FOR ARCHITECTURAL

DETAILS

A. M. BLANCHARD, Chairman; ARMSTRONG CHINN, HENRY LEHN, W. F. OGLE, Sub-Committee.

The Electrical Wiring Symbols as shown, Exhibit D, have been adopted by the National Electrical Contractors' Association and the American Institute of Architects and therefore it is the opinion of your SubCommittee that these symbols should be proposed for approval and adoption.

Below (see Exhibit E) is given a list of Architectural Symbols which have been prepared for conventional representations of architectural details. The information incorporated in the list has been gathered from all sources available and the best of the symbols have been shown.

439

Exhibit D

This specification is based upon the use of the following standard symbols adopted by the National Electrical Contractors' Association and the American Institute of Architects.

(Copyrighted.)

Ceiling Outlet; Electric coly. Numeral in center iddiantes number of Standard 16 C. P. Ioanndoscect Lampa

Ceiling Outlet: Combination. | indicates 4-16 C. P. Standard Incandescent Lamps and a Gas Burders. Il gas only

Bracket Outlet; Electric only. Numeral infcenter indicatos number of Standard 16 C. P. Incandescent Lamps.

[ocr errors]

Bracket Outlet; Combination. Sindicates!4-16 C. P. Standard loanndescent lamps and a Gas Burners. If gas only

[ocr errors]
[ocr errors]

Wall or Base Board Receptacle Outlet. Numeral in center indianier number of Standard 16 C. P. Incandescent Lampe.

Floor Outlet. Numeral in center indicatos aumber of Standard 16 C. P. Incandescent Lamps.

[ocr errors]

Outlet for Outdoor Standard or Pedestal; Electric only. Numeral indicates number of Standard 16 C. P. Incand't Lampe.

[ocr errors]

Outlet for Outdoor Standard or Pedestal; Combination. & indicates 6-16 C. P. Standard locand't Lamps; 6 Gas Burders.

Drop Cord Outlet,

One Light Outlot, for Lamp Roceptacle.

Arc Lamp Outlet.

Special Outlet, for Lighting, Heating and Power Current, as described in Specifications

Ceiling Fan Outlet

S'
S2
S3 3.Way Switch Outlet.
S4
So
Se

SP. Switch Outlet

D. P. Switch Outlet.

Show as many Symbols as there are Switches. Or in case of a very large group

of Switches, indicate number of Switches by a Roman numeral, thao SI XII; meaning 12 Single Pole Switches.

4-Way Switch Outlet

Describe Type of Switch in Specifications, that is,

Flush or Surface, Push Buttop or Snap.

Automatic Duor Switch Outlet

Electrolier Switch Outlet

Meer Outlet

Distribution Panel

Junction or Pull Box

Motor Outlet; Numeral in center indicates Horse Power.

Motor Control Outlet.

Tragsformer

Main or Feeder run concealed under floor.

Main or Feeder run concealed under Floor above.

Heights of Center of Wall Oatlets (unless otherwise
specified):
Living Rooms

sit. 6 ins

Main or Feeder run exposed.

Chambers

sit. oins,

Branch Circuit run concealed under Floor.

Offices

6 ft, o ias

Branch Circuit run concealed under Floor above.

Corridors

6 ft. 3 ins. Height of Switches (unless otherwise specified)

Branch Circuit run exposed.

. ft. o ini

Pole Line

River