| New York (N.Y.) - Building laws - 1901 - 186 pages
...said staircase. No door shall open immediately upon a flight of stairs, but a landing at least (he width of the door shall be provided between such stairs and such door. A fire-wall, built of brick, shall separate the auditorium from the stage, and the same shall... | |
| Brookline (Mass.). - Building laws - 1903 - 142 pages
...staircases from each tier shall be the full width of said staircase. No door shall open immediately upon a flight of stairs, but a landing at least the...door shall be provided between such stairs and such door. A fire wall built of brick shall separate the auditorium from the stage and the same shall extend... | |
| New York (State) - Session laws - 1904 - 1146 pages
...constructed with straight runs, changes in direction being made by platforms. No door shall open immediately upon a flight of stairs, but a landing at least the...be provided between such stairs and such doorway. § 2. This act shall take effect immediately. Chap, 2S2. AN ACT to amend section three thousand three... | |
| New York (State) - Law - 1904 - 1066 pages
...constructed with straight runs, changes in direction being made by platforms. No door shall open immediately upon a flight of stairs, but a landing at least the width of tiie door shall be provided between such stairs and such doorway. (Amended by L. 1!K)4, ch. 281, in... | |
| University of the State of New York - Education - 1905 - 576 pages
...constructed with straight runs, changes in direction being made by platforms. No door shall open immediately upon a flight of stairs, but a landing at least the...be provided between such stairs and such doorway. vyand '§18 Whenever a majority of the inhabitants of any school i "To 'install- district entitled... | |
| Building laws - 1905 - 274 pages
...said staircases from each tier shall be the full width of staircase. No door shall open immediately upon a flight of stairs, but a landing at least the...door shall be provided between such stairs and such door. A fire-wall, built of brick, not less than twelve proscenium inches in any portion of same shall... | |
| Education - 1905 - 848 pages
...nosing. Handrails shall be provided on both sides of all staircases. No doors shall open immediately upon a flight of stairs, but a landing at least the...door shall be provided between such stairs and such door. Every place of public assemblage accommodating five hundred shall have at least two exits of... | |
| Law - 1905 - 468 pages
...staircases from each tier shall be the full width of each staircase. No door shall open immediately upon a flight of stairs, but a landing at least the...door shall be provided between such stairs and such door. A fire wall, built of brick, shall separate the auditorium from the stage, and the same shall... | |
| Portland (Or.) - Devlin, Thomas C. - 1905 - 688 pages
...said staircases from each tier shall be full width of said staircases. No door shall open immediately upon a flight of stairs, but a landing at least the width of the door shall be provided between such stair and such door. (Construction of Balconies and Stairways.) SECTION 5. All the above-mentioned... | |
| Pennsylvania. State Board of Health and Vital Statistics - Pennsylvania - 1906 - 682 pages
...with straight runs, changes in directions being made by platforms. No doors shall open immediately upon a flight of stairs, but a landing at least the...be provided between such stairs and such doorway. Sec. 2. This act shall take effect immediately. — Engineering Review, April, 1904. Your committee... | |
| |