When the shearing stresses developed in any part of a construction exceed the safe working strength of concrete, as fixed in these Regulations, a sufficient amount of steel shall be introduced in such a position that the deficiency in the resistance to... Proceedings of the City Council ... - Page 2399by Chicago (Ill.). City Council - 1905Full view - About this book
| W. M. PATTON, C.E. - 1893 - 700 pages
...concrete-steel construction exceed the safe working strength of concrete, as fixed in these Regulations, a sufficient amount of steel shall be introduced in...deficiency in the resistance to shear is overcome. 16. When the safe limit of adhesion between the concrete and steel is exceeded, some provision must... | |
| William Macfarland Patton - Concrete - 1893 - 688 pages
...shall be introduced in such a position that the deficiency in the resistance to shear is overcome. 16. When the safe limit of adhesion between the concrete and steel is exceeded, some provision must be made for transmitting the strength of the steel to the concrete. 17. Concrete-steel may be... | |
| Louis Carlton Sabin - Cement - 1904 - 532 pages
...part of a construction exceed the safe working strength of concrete, as fixed in these Regulations, a sufficient amount of steel shall be introduced in...the concrete and steel is exceeded, some provision must be made for transmitting the strength of the steel to the concrete. "Concrete-steel may be used... | |
| Louis Carlton Sabin - Cement - 1904 - 536 pages
...part of a construction exceed the safe working strength of concrete, as fixed in these Regulations, a sufficient amount of steel shall be introduced in...the concrete and steel is exceeded, some provision must be made for transmitting the strength of the steel to the concrete. "Concrete-steel may be used... | |
| Louis Carlton Sabin - Cement - 1904 - 528 pages
...part of a construction exceed the safe working strength of concrete, as fixed in these Regulations, a sufficient amount of steel shall be introduced in...deficiency in the resistance to shear is overcome. steel is exceeded, some provision must be made for transmitting the strength of the steel to the concrete.... | |
| Charles Fleming Marsh - Reinforced concrete - 1904 - 582 pages
...shearing stress developed in any part of a construction exceeds the safe working strength of the concrete, a sufficient amount of steel shall be introduced in...that the deficiency in the resistance to shear is provided for. (9) When the safe limit of adhesion between the concrete and steel is exceeded, some... | |
| Charles Fleming Marsh - Reinforced concrete - 1904 - 580 pages
...shearing stress developed in any part of a construction exceeds the safe working strength of the concrete, a sufficient amount of steel shall be introduced in...that the deficiency in the resistance to shear is provided for. (9) When the safe limit of adhesion between the concrete and steel is exceeded, some... | |
| Cleveland, O. - 1904 - 276 pages
...concrete as fixed in this Code, a sufficient amount of steel, of such shape as to assure a mechamcal bond, shall be introduced in such a position that the deficiency in the resistance to shear is overcome, provided that all shear members are rigidly secured to the main horizontal reenforcing member. (d)... | |
| Chicago (Ill.) - 1905 - 1000 pages
...the construction, shall not exceed the safe working strength of the concrete as fixed in this chapter or a sufficient amount of steel shall be introduced...transmitting the strength of the steel to the concrete. 551. Columns — reinforced concrete.] Reinforced concrete may be used for columns when the ratio of... | |
| Peter Bonnett Wight, William Clendenin - Building, Fireproof - 1905 - 574 pages
...constructed building exceed under the multiplied loads, the shearing strength as fixed in this section, a sufficient amount of steel shall be introduced in...adhesion between the concrete and steel is exceeded, provision must be made for transmitting the strength of the steel to the concrete. Concrete-steel may... | |
| |