Proceedings of the Annual Convention of the American Railway Engineering and Maintenance-of-Way Association, Volume 23The Association, 1922 - Railroads List of members in v. 1- |
From inside the book
Results 1-5 of 100
Page 68
... floor area . ( These various elements , for con- venience , will hereafter be referred to as factors of design . ) If this is not done , and inadequate facilities are provided , it is very probable that the future effectivness of the ...
... floor area . ( These various elements , for con- venience , will hereafter be referred to as factors of design . ) If this is not done , and inadequate facilities are provided , it is very probable that the future effectivness of the ...
Page 69
... Floors . Shipping Plat- form ( Note B ) AREA OF FLOOR SPACE , SQUARE FEET ( Gross - No Deductions Made for Columns , Elevators , etc. ) Storage Space Served by Total Storage Elevators Space ( Note C ) ( Note D ) Number of Freight ...
... Floors . Shipping Plat- form ( Note B ) AREA OF FLOOR SPACE , SQUARE FEET ( Gross - No Deductions Made for Columns , Elevators , etc. ) Storage Space Served by Total Storage Elevators Space ( Note C ) ( Note D ) Number of Freight ...
Page 70
... floors in height , the question of speed is not as vital as in some other classes of buildings . In arriving at a suggested area of warehouse floor space per elevator , it is assumed that elevators will be installed of a size sufficient ...
... floors in height , the question of speed is not as vital as in some other classes of buildings . In arriving at a suggested area of warehouse floor space per elevator , it is assumed that elevators will be installed of a size sufficient ...
Page 71
... FLOOR AREA SERVED PER ELEVATOR Square Feet Floor Area Served per Elevator Size of Elevator Ware- house Number of Recommended No. Tenants Present by Operating Officials in Capacity of 3'x6 ' Trucks REMARKS 60,000 11 50,450 12 57,600 ...
... FLOOR AREA SERVED PER ELEVATOR Square Feet Floor Area Served per Elevator Size of Elevator Ware- house Number of Recommended No. Tenants Present by Operating Officials in Capacity of 3'x6 ' Trucks REMARKS 60,000 11 50,450 12 57,600 ...
Page 72
... floor area of 40,000 sq . ft . per elevator is a reasonable allowance . ( This allow- ance might be increased to 60,000 sq . ft . per elevator where the warehouse is used for storage purposes only . ) It might be added in this ...
... floor area of 40,000 sq . ft . per elevator is a reasonable allowance . ( This allow- ance might be increased to 60,000 sq . ft . per elevator where the warehouse is used for storage purposes only . ) It might be added in this ...
Contents
131 | |
159 | |
164 | |
165 | |
166 | |
167 | |
168 | |
225 | |
232 | |
263 | |
393 | |
427 | |
447 | |
483 | |
490 | |
784 | |
899 | |
18 | |
23 | |
28 | |
44 | |
59 | |
72 | |
86 | |
91 | |
99 | |
106 | |
177 | |
187 | |
Other editions - View all
Common terms and phrases
American Railway Association American Railway Engineering Appendix ash pit average ballast boiler bolts bridges capacity cars Cast Iron cent Chairman circuits classification yard Cleaning Clearance Committee recommends concrete connection construction Contractor cost crane crossing diameter double track Electric Electrolysis elevator engine house equipment feet fire floor freight house gang Grooved handling Illinois Central Railroad inch inspection installed length load located locomotive Manual material Maximum metal method Mikado miles Minimum motor operation paint passenger pipe plans plates platform rail railroad Railway Age Railway Engineering Association repair road Shawinigan Falls shifts-Total side space specifications spikes standard Steam steel storage Sub-Committee submitted surface swing bridges switches terminal tion Total traffic trains transfer table Transverse Fissures Trolley trucks valve vertical lift bridges wall Wallace warehouse weight width wire Wood yard
Popular passages
Page 550 - The manufacturer shall afford the inspector, without charge, all reasonable facilities to satisfy him that the material is being furnished in accordance with these specifications. All tests and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not to interfere unnecessarily with the operation of the works.
Page 505 - The purchaser may make the tests to govern the acceptance or rejection of the material in his own laboratory or elsewhere. Such tests, however, shall be made at the expense of the purchaser.
Page 43 - Be it further Resolved, That this resolution be spread upon the minutes of this meeting and that certified copies be sent to Hon.
Page 541 - The provisions of this agreement shall Inure to the benefit of and be binding upon the successors and assigns of the parties.
Page 1116 - Howard said he desired to call the attention of the members of the Association to the fact that this was the most representative meeting of the Association ever held.
Page 520 - For smaller sizes of pipes the letters may be 1 inch in length. The weight and the class letter shall be conspicuously painted in white on the inside of each pipe and special casting after the coating has become hard. ALLOWABLE PERCENTAGE OF VARIATION IN WEIGHT. SECTION 7. No pipe shall be accepted the weight of which shall be less than the standard...
Page 479 - Fine aggregate shall consist of sand, stone screenings, or other inert materials with similar characteristics, or a combination thereof, having clean, hard, strong, durable, uncoated grains and free from injurious amounts of dust, lumps, soft or flaky particles, shale, alkali organic matter, loam or other deleterious substances.
Page 126 - ... to that test. If either of these two additional specimens fails, the lot of tape represented by that sample shall be rejected. NOMINAL MINIMUM MINIMUM WEIGHT NET WEIGHT LENGTH PER ROLL, PER 100 PER POUND, LB. ROLLS, LB.
Page 524 - Specimen bars of the metal used, each being 26 inches long by 2 inches wide and i inch thick, shall be made without charge as often as the engineer may direct, and, in default of definite instructions, the contractor shall make and test at least one bar from each heat or run of metal. The bars, when placed flatwise upon supports 24 inches apart and loaded in the...
Page 519 - All pipes having the same outside diameter shall have the same inside diameter at both ends. The inside diameter of the lighter pipes of each standard outside diameter shall be gradually increased for a distance of about 6 inches from each...