Proceedings of the Annual Convention of the American Railway Engineering and Maintenance-of-Way Association, Volume 23The Association, 1922 - Railroads List of members in v. 1- |
From inside the book
Results 1-5 of 100
Page 6
... Cast Iron Pipe and Special Castings ...... University Work in Connection with Railway Water Supply .... 508 514 527 REPORT ON UNIFORM GENERAL CONTRACT FORMS ..... 529 Revision of Manual .................. . 534 Form of License for Wires ...
... Cast Iron Pipe and Special Castings ...... University Work in Connection with Railway Water Supply .... 508 514 527 REPORT ON UNIFORM GENERAL CONTRACT FORMS ..... 529 Revision of Manual .................. . 534 Form of License for Wires ...
Page 173
... cast steel which can be fabricated by the common shop methods of punching , reaming , drilling , boring , shearing ... cast supports , shafts , spools , gears , racks , bearings , couplings , clutches , brakes ( unless part of the motors ) ...
... cast steel which can be fabricated by the common shop methods of punching , reaming , drilling , boring , shearing ... cast supports , shafts , spools , gears , racks , bearings , couplings , clutches , brakes ( unless part of the motors ) ...
Page 175
... CAST STEEL : For rim girder tread plates , levers , cranks , connecting rods , and rollers . FORGED STEEL : For pinions and equalizing levers . CAST STEEL : For pivot stands , couplings , wedges , wedge bearings , trailing wheels , end ...
... CAST STEEL : For rim girder tread plates , levers , cranks , connecting rods , and rollers . FORGED STEEL : For pinions and equalizing levers . CAST STEEL : For pivot stands , couplings , wedges , wedge bearings , trailing wheels , end ...
Page 176
... cast iron . In power operated bridges , the permission to use cast iron shaft bearings applies only to line shaft bear- ings carrying the weight of the shafting only . Cast iron shall not be used for couplings , for trunnion supports of ...
... cast iron . In power operated bridges , the permission to use cast iron shaft bearings applies only to line shaft bear- ings carrying the weight of the shafting only . Cast iron shall not be used for couplings , for trunnion supports of ...
Page 180
... Cast steel 7,000 8,000-35 : 10,000 5,000 Phosphor - bronze 6,000 6,000 4.500 Cast iron 1,500 8,000 * 8,000 2,000 Keys * For struts whose is 20 or less . - ↑ 9,000 5,000 Loads . Unit Stresses and Proportioning of Parts . For 180 Iron ...
... Cast steel 7,000 8,000-35 : 10,000 5,000 Phosphor - bronze 6,000 6,000 4.500 Cast iron 1,500 8,000 * 8,000 2,000 Keys * For struts whose is 20 or less . - ↑ 9,000 5,000 Loads . Unit Stresses and Proportioning of Parts . For 180 Iron ...
Contents
131 | |
159 | |
164 | |
165 | |
166 | |
167 | |
168 | |
225 | |
232 | |
263 | |
393 | |
427 | |
447 | |
483 | |
490 | |
784 | |
899 | |
18 | |
23 | |
28 | |
44 | |
59 | |
72 | |
86 | |
91 | |
99 | |
106 | |
177 | |
187 | |
Other editions - View all
Common terms and phrases
American Railway Association American Railway Engineering Appendix ash pit average ballast boiler bolts bridges capacity cars Cast Iron cent Chairman circuits classification yard Cleaning Clearance Committee recommends concrete connection construction Contractor cost crane crossing diameter double track Electric Electrolysis elevator engine house equipment feet fire floor freight house gang Grooved handling Illinois Central Railroad inch inspection installed length load located locomotive Manual material Maximum metal method Mikado miles Minimum motor operation paint passenger pipe plans plates platform rail railroad Railway Age Railway Engineering Association repair road Shawinigan Falls shifts-Total side space specifications spikes standard Steam steel storage Sub-Committee submitted surface swing bridges switches terminal tion Total traffic trains transfer table Transverse Fissures Trolley trucks valve vertical lift bridges wall Wallace warehouse weight width wire Wood yard
Popular passages
Page 550 - The manufacturer shall afford the inspector, without charge, all reasonable facilities to satisfy him that the material is being furnished in accordance with these specifications. All tests and inspection shall be made at the place of manufacture prior to shipment, unless otherwise specified, and shall be so conducted as not to interfere unnecessarily with the operation of the works.
Page 505 - The purchaser may make the tests to govern the acceptance or rejection of the material in his own laboratory or elsewhere. Such tests, however, shall be made at the expense of the purchaser.
Page 43 - Be it further Resolved, That this resolution be spread upon the minutes of this meeting and that certified copies be sent to Hon.
Page 541 - The provisions of this agreement shall Inure to the benefit of and be binding upon the successors and assigns of the parties.
Page 1116 - Howard said he desired to call the attention of the members of the Association to the fact that this was the most representative meeting of the Association ever held.
Page 520 - For smaller sizes of pipes the letters may be 1 inch in length. The weight and the class letter shall be conspicuously painted in white on the inside of each pipe and special casting after the coating has become hard. ALLOWABLE PERCENTAGE OF VARIATION IN WEIGHT. SECTION 7. No pipe shall be accepted the weight of which shall be less than the standard...
Page 479 - Fine aggregate shall consist of sand, stone screenings, or other inert materials with similar characteristics, or a combination thereof, having clean, hard, strong, durable, uncoated grains and free from injurious amounts of dust, lumps, soft or flaky particles, shale, alkali organic matter, loam or other deleterious substances.
Page 126 - ... to that test. If either of these two additional specimens fails, the lot of tape represented by that sample shall be rejected. NOMINAL MINIMUM MINIMUM WEIGHT NET WEIGHT LENGTH PER ROLL, PER 100 PER POUND, LB. ROLLS, LB.
Page 524 - Specimen bars of the metal used, each being 26 inches long by 2 inches wide and i inch thick, shall be made without charge as often as the engineer may direct, and, in default of definite instructions, the contractor shall make and test at least one bar from each heat or run of metal. The bars, when placed flatwise upon supports 24 inches apart and loaded in the...
Page 519 - All pipes having the same outside diameter shall have the same inside diameter at both ends. The inside diameter of the lighter pipes of each standard outside diameter shall be gradually increased for a distance of about 6 inches from each...