Page images
PDF
EPUB

which can be cut from the smaller timber is a measure of conservation in that it increases the number of trees which can supply stringer material. Eight in. by 8 in. ties are shown because their use was indicated by more designs submitted than all other sizes put together. Tenfoot length was chosen because while in the number of designs the nine and ten-foot length were nearly equal, many more were using longer lengths of 11, 12, 13, and 14 feet than those using shorter lengths of 8 and 81⁄2 feet. The ten-foot tie is also a better tie to use for the fourstringer chord.

Ties fastened every third tie appeared to be in more common use than other spacings and was deemed ample. Drift bolts were indicated in plans recommended in 1918 for fastening the ties to the stringers and were adopted by this Committee because of the maintenance required on bolts if used.

Five in. by 8 in. guard timbers were used because a six inch timber would encroach on the clearance diagram. The use of lag screws to fasten guard timber to ties is in accordance with previous A.R.E.A. recommendations.

The use of separator blocks of either metal or wood between the ties is recommended as worthy of further investigation and study.

Drift bolts are shown for fastening stringers to caps because this method is used by railroads as indicated by replies to questionnaire almost twice as often as all other methods put together. The Committee recommends that only one drift bolt be used in an intersection of chord with cap, feeling that one is sufficient and that more only increased the chance for decay and difficulty of realignment if necessary.

The Committee recommends four-pile bent for the light 12-foot span, five-pile bent for the heavy 12-foot span, five-pile bent for the light 16-foot span and six-pile bent for the heavy 16-foot span, and that the same number of posts be used in timber bents as for the corresponding spans and loadings of the pile bent designs. This gives a consistent series considering the loading and spans without excessive pile loading. All but the center one or two piles are shown driven on a batter to give greater stiffness to the bent.

Elevation on curves is best secured by cut-offs of posts or piles rather than by shims or tapered ties.

Three in. by 10 in. sway bracing is used as shown in returns almost in ratio of 3 to 1 of all other sizes together.

The 12 in. by 14 in. cap is used in more plans than all other sizes put together, and was used by the Committee for the lighter loading, but the Committee felt that under the heavier loading the 14 in. by 14 in. cap was to be preferred to give greater end bearing areas.

Where concrete footings may be used, the Committee has shown a design with the posts butting or resting directly on the concrete, thereby eliminating the sill. It usually early shows weakness by decay and compression. Horizontal braces above the concrete tie the posts together and dowels are used to hold the bent in line on the concrete and to

aid the transfer of longitudinal stresses of the trestle to the foundation. Concrete foundations under frame bents may be made as shown on drawings or as solid piers, depending on the cost of each.

The Committee recommends that where long round timber can be secured that it is good practice to use as long posts as possible to avoid multiple-story bents leaving out the horizontal sills.

Longitudinal horizontal girts are shown 6 in. by 10 in. because it is desirable that a stiff strut with ample bolting area be used. The Committee submitted the plan of lapping the girts by on the posts with double through bolting and dapping over the sash brace on the bent because in their judgment all forms of end to end arrangements of girts did not leave enough material to make secure the bolt fastenings and because of shrinkage of material it is difficult to keep the end contact tight, which is necessary if the brace is to be effective.

Longitudinal diagonal bracing are shown 3 in. by 10 in., as this size seems to be used by more roads than all those using other sizes put together.

There were many different layouts of longitudinal diagonal bracing indicated in replies to questionnaire, but the Committee recommended the bracing in every third panel for pile bents and in every other panel for frame bents as being sufficient in ordinary circumstances. High trestles require more and are indicated in the plan for multiple story trestles.

In constructing bulkhead at the ends of wooden trestles the Committee recommends as good practice the use of sections of old rail as separators between piles or posts and end planking.

The Committee in presenting plans for ballast deck timber trestles has not had as much material information from railroads' experience because this type of deck is more recent in its development and has not been as extensively used as the open deck. The Committee, therefore, presents a compromise of the best features.

The Committee felt that experience indicates that the open system of stringers with plank covering was the better type because of convenience of repair, less tendency to decay and the economical use of stringer material.

The Committee chose the single span length stringer lapping by on the caps the full width of cap because this plan enables the use of shorter timbers, the removal and repair of one panel at a time, and where creosoted timber is used, the avoidance of cutting the stringers after treatment.

The stringers are shown laid skew, which arrangement develops a more symmetrical loading of the stringer at the center of the span.

With the stringers held in place by planks spiked to them, it was decided that four drift bolts would be sufficient at each bent to hold deck to caps.

In the replies returned to questionnaire there were as many 14-foot decks as all other widths put together and the Committee therefore chose the 14-foot width.

There was no great predominance of any one span length but 13 ft. and 13 ft. 6 in. represented five out of fifteen plans, 14 ft., 14 ft. 6 in., and 15 ft. represented six out of fifteen plans but the Committee did not want to use larger than 8 in. by 16 in. stringers nor stresses higher than the value given below. Eight in. by 16 in. stringers with E-60 loading on deck have a calculated fiber stress of 1,470 lb. per square inch of possible actual size.

The Committee decided on six piles or posts to the bent because of the increased dead load carried and the natural greater permanence of this type of structure.

The use of 12 in. by 14 in. caps exceeded in number all other sizes together, as did also the use of 16-foot length caps.

The ballast curb was chosen 8 in. wide because the use of this width exceeded all other widths put together, while the Committee chose 8 in. for height in face of the fact that the larger number of plans showed only 6 in. high because the ballast should be retained better than would be done by a 6 in. curb.

Four-inch planking was thought would give a better distribution of loading over the stringers.

[graphic][merged small][subsumed][ocr errors][ocr errors][subsumed][ocr errors][subsumed][ocr errors][ocr errors][subsumed][subsumed][ocr errors][ocr errors][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][ocr errors][subsumed][merged small][ocr errors][ocr errors][subsumed][subsumed][subsumed][subsumed][ocr errors][subsumed][subsumed][ocr errors][ocr errors][subsumed][subsumed][subsumed][subsumed]
[graphic][merged small][ocr errors][ocr errors][subsumed][subsumed][ocr errors][subsumed][subsumed][subsumed][ocr errors][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][ocr errors][subsumed][ocr errors][ocr errors][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][subsumed][merged small][ocr errors][subsumed][subsumed]
« PreviousContinue »