" No. 51.) a. Must be placed on all service wires, either overhead or underground in a readily accessible place, as near as possible to the point where the wires enter the building, and arranged to cut off the entire current. "
Science and Industry - Page 258
1902
Full view - About this book

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - Electric engineering - 1897 - 710 pages
...placed on all service wires, either overhead or underground, in a readily accessible place, as near as possible to the point where the wires enter the...building, and arranged to cut off the entire current. 6. Must always be placed in dry. accessible places, and be grouped as far as possible. K.nife switches...
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volume 19

American Society of Mechanical Engineers - Mechanical engineering - 1898 - 1122 pages
...placed on all service wires, either overhead or underground, in a readily accessible place, as near as possible to the point where the wires enter the...building and arranged to cut off the entire current. I. Must always be placed in dry, accessible places, and be grouped as far as possible. Knife switches...
Full view - About this book

Distributing system and lamps

Francis Bacon Crocker - Electric lighting - 1901 - 528 pages
...placed on all service wires, either overhead or underground in a readily accessible place, as near as possible to the point where the wires enter the...building, and arranged to cut off the entire current. b. Must always be placed in dry, accessible places, and be grouped as far as possible. Knife switches...
Full view - About this book

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - Electrical engineering - 1901 - 1018 pages
...placed on all service wires, either overhead or underground, in a readily accessible place, as near as possible to the point where the wires enter the...building, and arranged to cut off the entire current. 6. Must always be placed in dry, accessible places, and be grouped as far as possible. Knife switches...
Full view - About this book

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - Electric wiring - 1902 - 204 pages
...placed on all service wires, either overhead or underground, in a readily accessible. place, as near as possible to the point where the wires enter the...arranged to cut off the entire current. Knife switches should always be installed so that the handle will be up when the circuit is closed, so An Approved...
Full view - About this book

International Library of Technology: A Series of Textbooks for ..., Volume 13

Agriculture - 1902 - 738 pages
...placed on all service wires, either overhead or underground, in a readily accessible place, as near as possible to the point where the wires enter the...building, and arranged to cut off the entire current. b. Must always be placed in dry, accessible places and be grouped as far as possible. Knife switches...
Full view - About this book

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - Fire insurance - 1902 - 230 pages
...placed on all service wires, either overhead or under ground, in a readily accessible place, as near as possible to the point where the wires enter the...building, and arranged to cut off the entire current, and must always be placed in dry, accessible places, and be grouped as far as possible. Knife switches...
Full view - About this book

International Library of Technology: A Series of Textbooks for Persons ...

Agriculture - 1902 - 742 pages
...entire current. b. Must always be placed in dry, accessible places and be grouped as far as possible. Knife switches must be so placed that gravity will tend to open rather than close the switch. c. Must not be single-pole when the circuits that they control supply devices that require over 660...
Full view - About this book

Les recueils de jurisprudence du Québec, publiés par le Barreau de ..., Volume 1

Québec (Province). Superior Court - Law reports, digests, etc - 1902 - 642 pages
...placed on all service wires, cither " overhead or underground, in a readily accessible place, as " near as possible to the point where the wires enter the " building, and arranged to cut off the'entire current." Rule 21, as to "automatic cut-outs," is to the like effect. To reach the switches...
Full view - About this book

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - Electricity - 1903 - 320 pages
...placed on all service wires, either overhead or underground, in a readily accessible place, as near as possible to the point where the wires enter the...arranged to cut off the entire current. Knife switches should always be installed so that the handle will be up when the circuit is closed, so that gravity...
Full view - About this book




  1. My library
  2. Help
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF