| Materials - 1916 - 806 pages
...bars. Tension test specimens shall conform to the dimensions shown in Fig. 1. The ends shall be of a form to fit the holders of the testing machine in such a way that the load Radius not /ess ,! I f? i ^ i * i . C 1 f . i , 1 ( i I ' ! ,- ..' !'. .\ 'м '. l!lv,,4fr III M«... | |
| United States. Bureau of Aircraft Production - Aeronautics, Military - 1918 - 390 pages
...test for specimens for bars shall conform to the dimensions shown in Fig. 1. The ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Test / specimens representing heat-treated or brittle materials shall have Materials... | |
| Materials - 1918 - 992 pages
...bar. Tension test specimens shall conform to the dimensions shown in Fig. 2. The ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Bend test specimens shall be 1 by £ in. in section. (e) Tension and bend test specimens... | |
| Carnegie Steel Company - Building, Iron and steel - 1919 - 456 pages
...thickness or diameter may conform to the dimensions shown in fig. 2. In this case the ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Bend-test specimens may be 1 by J^ inch in section. The axis of the specimens shall... | |
| Pollak Steel Company - Axles - 1919 - 206 pages
...drawn out. (c) The specimens shall conform to the dimensions shown in Fig. 1. The ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. NUMBER OF TESTS. 12. Unless otherwise specified by the purchaser, tests shall be made... | |
| Arthur William Judge - Aeronautics - 1919 - 1130 pages
...tests for specimens for bars shall conform to th« dimensions shown in Fig. 1. The ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial; test specimens representing heat-treated or brittle materials shall have threaded ends... | |
| George A. Hool, Nathan C. Johnson - Building - 1920 - 684 pages
...thickness or diameter may conform to the dimensions shown in Fig. 2. In this case, the ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Bend test specimens may be 1 by H in. in section. The aids of the specimen shall be... | |
| Association of American Railroads. Mechanical Division - 1920 - 992 pages
...represents. (b) The specimens shall conform to the dimensions shown in Fig. I. The ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Radius not less than i/e» 2*4 inch-- G«ge LengthFIG. i. 8. Number of Tests. — (a)... | |
| Arthur William Judge - Airplanes - 1920 - 780 pages
...test for specimens for bars shall conform to the dimensions shown in Fig. 32. The ends shall be of a form to fit the holders of the testing machine in such a way that the B T CL I ,0-2.5 Xact FIQ. 32. load shall be axial; test specimens representing heat-treated or brittle... | |
| Milo Smith Ketchum - Building, Iron and steel - 1921 - 672 pages
...thickness or diameter may conform to the dimensions shown in Fig. 2. In this case, the ends shall be of a form to fit the holders of the testing machine in such a way that the load shall be axial. Bend test specimens may be 1 by J in. in section. The axis of the specimen shall be... | |
| |