| New England Water Works Association - Water-supply - 1902 - 508 pages
...so as to read, " And if the pipe is not inspected at the works by the engineer, the contractor shall furnish a sworn statement that all of the tests have been made and the requirements fulfilled, and if the pipe is specially cast to fill a given order the specific... | |
| Iron - 1904 - 704 pages
...inspection and weighing at the foundry of the pipes and special castings ; and, should the purchaser have no inspector at the works, the contractor shall,...statement to contain the results of the tests upon the test-bars. Class A Pipe 2Olnch Diameter and Larger Pounds per Sq. Inch Less than 2o.inch Diameter Pounds... | |
| Nisbet Latta - Gas manufacture and works - 1907 - 502 pages
...inspection, and weighing at the foundry of the pipes and special castings; and, should the purchaser have no inspector at the works, the contractor shall,...statement to contain the results of the tests upon the testbars. POWER OF ENGINEER TO INSPECT. SECTION 17. The engineer shall be at liberty at all times to... | |
| American Society for Testing Materials - Building materials - 1910 - 326 pages
...inspection and weighing at the foundry of the pipes and special castings; and, should the purchaser have no inspector at the works, the contractor shall, if required by the engineer, furnish a sworn Class A pipe Class C pipe ... .... Class D pipe statement that all of the tests have been made as specified,... | |
| Building materials - 1913 - 420 pages
...inspection and weighing at the foundry of the pipes and special castings; and, should the purchaser have no inspector at the works, the contractor shall, if required by the engineer, furnish a swom * 20- Inch Diameter and Larger. Ibs. per sq. in. Less than zo-Inch Diameter. Ibs. per sq. in.... | |
| American Gas Institute - Gas - 1914 - 936 pages
...inspection and weighing at the foundry of the pipe and special castings ; and should the purchaser have no inspector at the works, the contractor shall,...the test bars. Power of Engineer to Inspect. Section 15. The engineer shall be at liberty at all times to inspect the material at the foundry, and the molding... | |
| David Wells Payne - Founding - 1917 - 724 pages
...pounds per square inch Less than 2o-inch diameter, pounds per square inch Classes 150 300 300 300 300 no inspector at the works, the contractor shall, if...tests upon the test bars. Power of Engineer to Inspect The engineer shall be at liberty at all times to inspect the material at the foundry, and the moulding,... | |
| Materials - 1918 - 992 pages
...inspection and weighing at the foundry of the pipes and special castings; and, should the purchaser have no inspector at the works, the contractor shall,...sworn statement that all of the tests have been made 20-In. Diameter and Larger, Ib. per aq. in. Lem th»n 20-In. Diameter, Ib. per sq. in. 150 800 200... | |
| Municipal engineering - 1902 - 600 pages
...inspection and weighing at the foundry of the pipes and special castings; and, should the purchaser have no inspector at the works, the contractor shall, if required by the ( nglneer, furnish a sworn statement that all of the tests have been made as specified, this statement... | |
| |