Transactions of the American Institute of Electrical Engineers, Volume 34American Institute of Electrical Engineers., 1915 - Electric engineering "Index of current electrical literature," Dec. 1887- appended to v. 5- |
From inside the book
Results 1-5 of 100
Page 1459
... given apply to the New Haven construction which was installed in the section with greatest traffic density , also through thickly settled communities . Therefore , the figures given will be of little value for comparison or estimating ...
... given apply to the New Haven construction which was installed in the section with greatest traffic density , also through thickly settled communities . Therefore , the figures given will be of little value for comparison or estimating ...
Page 1523
... given several coats of paint after installation ; that used in this latter installation was given two coats of hot creosote . Trolley Wire . Originally , a trolley wire of span 1915 ] 1523 DUER : CONTACT SYSTEMS.
... given several coats of paint after installation ; that used in this latter installation was given two coats of hot creosote . Trolley Wire . Originally , a trolley wire of span 1915 ] 1523 DUER : CONTACT SYSTEMS.
Page 1531
... given in Table II . The maintenance cost of each system includes the amounts directly chargeable to that system and a pro rata charge for general expenses as follows : Superintendence ; Maintenance , Labor and Material ; Tools and ...
... given in Table II . The maintenance cost of each system includes the amounts directly chargeable to that system and a pro rata charge for general expenses as follows : Superintendence ; Maintenance , Labor and Material ; Tools and ...
Page 1533
... given in Table III , are the following : Single track Detentions Year miles of trolley Number Minutes 1908 19.56 230 2864 1910 9.56 63 927 1911 9.56 46 165 THIRD RAIL AND TRACK RESISTANCES Resistance of third and running rails ...
... given in Table III , are the following : Single track Detentions Year miles of trolley Number Minutes 1908 19.56 230 2864 1910 9.56 63 927 1911 9.56 46 165 THIRD RAIL AND TRACK RESISTANCES Resistance of third and running rails ...
Page 1547
... given , correspond- ing to the existing A. I. E. E. classification of contact conductors . Contact rail systems and ... given of constructions where consideration has been given to the factors discussed . Suggestions are made as to ...
... given , correspond- ing to the existing A. I. E. E. classification of contact conductors . Contact rail systems and ... given of constructions where consideration has been given to the factors discussed . Suggestions are made as to ...
Contents
1471 | |
1487 | |
1517 | |
1535 | |
1547 | |
1561 | |
1585 | |
1599 | |
2197 | |
2237 | |
2279 | |
2361 | |
2369 | |
2389 | |
2443 | |
2483 | |
1627 | |
1693 | |
1731 | |
1739 | |
1801 | |
1821 | |
1857 | |
1921 | |
1953 | |
2023 | |
2079 | |
2127 | |
2141 | |
2157 | |
2183 | |
2511 | |
2533 | |
2560 | |
2601 | |
2671 | |
2693 | |
2721 | |
2747 | |
2781 | |
vi | |
15 | |
40 | |
89 | |
Other editions - View all
Common terms and phrases
alternating current amount amperes apparatus applied armature average brush cable capacity catenary cent charges coil conductor connected considerable considered construction contactor copper corona cost curve customers cycles density determined dielectric direct current electric energy Engineers equation feeder field flux frequency given hanger heat impulse ratio increase indicated installed insulation load factor machines magnetic maximum demand measured meter method miles moisture mutual inductance necessary neutral normal obtained ohms operation overhead pantagraph paper phase power factor practically reactance relay resistance short circuit shown in Fig shunt sine wave skin effect slots spacing spark-over voltage sphere steam steel strain insulators strip substations supply switch Table telephone temperature terminals tests third harmonic third rail three-phase tion track transformer trolley wire tubes two-phase volts wattmeter winding zero